Subject and UNIT: Electric Circuit Analysis: Unit IV: Three phase circuits
The 3-phase voltage can be produced in a stationary armature with rotating field or in a rotating armature with a stationary field. 3-phase voltages are generated in three separate but identical sets of windings or coils which are displaced by 120 electrical degrees in the armature.
Electric Circuit Analysis | Transient Response Analysis
Subject and UNIT: Electric Circuit Analysis: Unit III: Transient Response Analysis
Electric Circuit Analysis: Unit III: Transient Response Analysis : Exercise
Worked Example Solved Problems
Subject and UNIT: Electric Circuit Analysis: Unit III: Transient Response Analysis
Electric Circuit Analysis: Unit III: Transient Response Analysis : Examples
Worked Example Solved Problems
Subject and UNIT: Electric Circuit Analysis: Unit III: Transient Response Analysis
Electric Circuit Analysis: Unit III: Transient Response Analysis : Worked examples
Subject and UNIT: Electric Circuit Analysis: Unit III: Transient Response Analysis
Electric Circuit Analysis: Unit III: Transient Response Analysis : Worked examples - Transients in RL, RC, RLC Circuit
Worked Example Solved Problems
Subject and UNIT: Electric Circuit Analysis: Unit III: Transient Response Analysis
Electric Circuit Analysis: Unit III: Transient Response Analysis : Worked examples
Steps, Worked Example Solved Problems
Subject and UNIT: Electric Circuit Analysis: Unit III: Transient Response Analysis
Electric Circuit Analysis: Unit III: Transient Response Analysis : D.C. Transients in RC Circuit : Worked examples
Worked Example Solved Problems
Subject and UNIT: Electric Circuit Analysis: Unit III: Transient Response Analysis
Electric Circuit Analysis: Unit III: Transient Response Analysis : Worked examples
Transient Response Analysis
Subject and UNIT: Electric Circuit Analysis: Unit III: Transient Response Analysis
Here we have three types of circuits. In each case the voltage applied (excitation) is assumed to be step voltage denoted by Eu (t). u (t) is the unit step voltage.
Transient Response Analysis
Subject and UNIT: Electric Circuit Analysis: Unit III: Transient Response Analysis
For a given circuit, we can obtain the differential equations by the applications of Kirchoff's law. Such equations can be solved by (a) Classical method, (b) Laplace transformation method and so on.
Transient Response Analysis
Subject and UNIT: Electric Circuit Analysis: Unit III: Transient Response Analysis
The procedure generally followed to determine the initial conditions consists of two steps in sequence.
Subject and UNIT: Electric Circuit Analysis: Unit III: Transient Response Analysis
We know that for a linear resistor VR = Ri. So, theoretically, the current through or the voltage across the resistor can change instantaneously, i.e., in zero time.